Title: New on-line rotor ground fault location method for synchronous machines with static excitation
Authors: C.A. Platero , F. Blázquez , P. Frías , M. Pardo
Keywords: AC generator excitation, fault location, power generation protection, synchronous generator excitation.
Research topics
Abstract: This paper presents a novel on-line rotor ground fault location method for synchronous machines, which, combined with rotor ground fault protection, can detect and locate faults in the rotor. This method is suitable for synchronous machines with static excitation systems, whose excitation field winding is fed by rectifiers through an excitation transformer. The main contribution of this new technique is that it can locate the position of a ground fault in the rotor winding online, reducing the repair time. The proposed technique is based on the analysis of the ac and dc components of the excitation voltage and the voltage measured in a grounding resistance located in the neutral terminal of the excitation transformer. This technique has been validated through computer simulations and experimental laboratory tests.
Reference: IEEE Transactions on Energy Conversion
Volume: 26   Number: 2   Pages: 572-580
Publication date:June 2011
DOI reference: DOI icon 10.1109/TEC.2010.2095501    
Journal Impact Factor: JCR impact factor 2.272 (2011)
Reference for EndNote:

Download paper:




© Comillas Pontifical University, ICAI School of Engineering, Institute for Research in Technology
Mailing Address: C/ Alberto Aguilera 23, 28015 Madrid, Spain
Building SM26: C/ Santa Cruz de Marcenado 26, 28015 Madrid, Spain MAP
Building FR3: C/ Francisco de Ricci 3, 28015 Madrid, Spain MAP
Contact Information: Tel: +34 91 542-2800, Fax: +34 91 542-3176, email: info@iit.upcomillas.es
Locations of visitors to this page