comillas comillas

EN Institute for Research in Technology — Instituto de Investigación Tecnológica IIT

español english browser default
Presentation Description Organization Personnel Activities Misc

Details of journal paper

Title: Influence of rotor position in FRA response for detection of insulation failures in salient-pole synchronous machines
Authors: C.A. Platero , F. Blázquez , P. Frías , D. Ramírez
Keywords: Fault diagnosis, fault location, frequency response analysis, synchronous machines.
Research topics
Abstract: Frequency response analysis (FRA) is a very common test for the diagnosis of power transformers. This paper presents some relevant results on the application of FRA to the diagnosis of rotating machines. First, a reference rotor position for obtaining the reference FRA response of a rotating machine is proposed. Then, FRA with the proposed rotor position is used to identify faults in the stator of the machine. This paper studies turn-to-turn and ground faults in the stator for different fault resistance values. Several laboratory tests demonstrate the applicability and value of the use of FRA in the diagnosis of rotating machines.
Reference: IEEE Transactions on Energy Conversion
Volume: 26   Number: 2   Pages: 671-676
Publication date:June 2011
DOI reference: DOI icon 10.1109/TEC.2011.2106214    
Journal Impact Factor: JCR impact factor 2.272 (2011)
Reference for EndNote:

Download paper:




© Comillas Pontifical University, ICAI School of Engineering, Institute for Research in Technology